Gary Thomas wrote:

> On Fri, 2001-11-09 at 00:46, Chandra Sekhar G wrote:
> > Hi,
> >
> >     We are using cs9800 controller on a custom designed board.  I am
> > able to run the TCP/IP loop back tests on this board.  In the present
> > configuration of eCos, when I see the object dump of a test program (not
> > a loop back program), the two global variables __NETDEVTAB__ and
> > __NETDEVTAB_END__ are having a same address.  This means, there are no
> > entries in the network device table.  I think, I am missing something
> > during the configuration of eCos.  Can anybody give me a clue?  I did
> > not configured any of the other devices.  I am using latest sources of
> > eCos.
>
> You'll need to provide a network driver structure for your controller.
> Look at the driver provided for the Cirrus Logic EDB7xxx family of
> processors for an example.
>   .../devs/eth/arm/edb7xxx/

Hi,

    The controller we are using is cs8900.  We are directly using the driver
code of ..../dev/eth/arm/edb7xx/, after putting in a proper directory
structure and a few modifications to the addresses.  All the related cdl
files are also identical.  Still the problem persists.

regards,
chandra