Re: Simple serial comms
Nick Garnett wrote:
>
> grahamlab <graham.labdon@cranems.co.uk> writes:
>
>>
>> I have tried flow control but to no avail
>> there must be a way to receive more than 128 bytes has anybody got any
>> other
>> suggestions
>
> Flow control should entirely solve your problem. Did you enable the
> same kind of flow control at both ends of the connection?
>
> I have run tests that successfully transfer larger quantities of data
> at higher baud rates for long periods. So I don't believe there is a
> significant problem with the basic driver code.
>
> Some other things to try:
>
> - Test against a host with a real RS232 device. USB adaptors can do
> weird things. It is worth eliminating this as a cause of problems,
> particularly with regard to flow control.
>
> - Try increasing STM32_RXBUFSIZE in the driver source to 128 or
> more. Also add a diag_printf() to the overflow branch in the ISR to
> see if it triggers.
>
> - Avoid diag_printf() calls while waiting for data. If you are running
> via GDB these calls can cause interrupts to be disabled while the
> output is being sent. This may cause the driver to miss characters.
>
> - It may be instructive to work out exactly which bytes are lost in
> each message. This may give a clue as to which FIFO or buffer is
> filling up.
>
>
>
I wont be able to test against a 'real' host until monday
I have tried a variety of values for STM32_RXBUFSIZE but nothing changes -
the overflow branch is not triggered
Is it possible for you to send me the programs you use to test the serial
interface?
Graham
--
View this message in context: http://www.nabble.com/Simple-serial-comms-tp24306125p24322375.html
Sent from the Sourceware - ecos-discuss mailing list archive at Nabble.com.
--